MULTI NOZZLE ( ORIFICE )LANCER DESUPERHEATER

Sizes : Mounting of the desuperheater in the steam pipeing of size 6" onward (regardless of pipe size) is always 4" and 1" (or 2") for water inlet.
Rangeability : 350 : 1 can be accomodated.
Rating : upto ANSI 2500#
Superior Water pressure : 5 bar above the line pressure OR high pressure BFW.
Actuator : Mazda R50 positioning cylinder.
Flow chracteristics : Modified, Equal % Linear
VARIABLE NOZZLE SPRAY DESUPERHEATER ( VA 6 )

Sizes : Mounting in the steam pipe of 6 onwards is always 3 and 1 (or 2) for water inlet.
Rangeability : 40:1
Rating : upto ANSI 2500#
Superior Water pressure : 5 bar above the line pressure OR high pressure BFW.
Actuator : Mazda R50 positioning cylinder.
Flow chracteristics : Modified, Equal % Linear
VENTURI AND DOUBLE VENTURI DESUPERHEATERS (6201 V AND 6201 DV)

Sizes : 2 to 30
Rangeability : 6 : 1 for single venturi type and 12 : 1 for double venturi.
Rating : upto ANSI 2500#
Superior Water pressure : Cooling water can be fed at steam operating pressure
ATTEMPERATOR (MA - 6202)

Sizes are between 1 1/2 to 30
IN - LINE VENTURI (MI - 6205)

sizes are between (16 to 40)
MINI VENTURI (MS - 6200)

Available in sizes 1/2 to 1 1/2,
Copyright ? 2006 Top Tec World Co.,Ltd. All rights reserved